Filter Housing Specifications
Flow Rating: Up to 120 gpm (455 L/min) for 150 SUS (32 cSt) fluids
Max. Operating Pressure: 300 psi (20 bar)
Min. Yield Pressure: 1000 psi (70 bar), per NFPA T2.6.1
Rated Fatigue Pressure: 250 psi (17 bar), per NFPA T2.6.1-2005
Temp. Range: -20°F to 225°F (-29°C to 107°C)
Bypass Setting: Cracking: 30 psi (2.1 bar) Full Flow: 60 psi (4.1 bar)
Weight of LC1-18LC: 17.5 lbs. (7.9 kg)
The LF1 can be used in a variety of industries including automotive manufacturing, machine tool, mobile vehicles and many more.
Elements available include;
18LC3, 18LC10
18LCZ1, 18LCZ3, 18LCZ5. 18LCZ10, 18LCZ25
If you would like any information or advice on any of our filters, please contact us.