Particle Pal Plus + Water PPM: Digital Imaging Portable Particle Counter

  • Particle Pal Plus logo
  • FS9V4-PPM

ON-SITE FUEL ANALYSIS

Our all new Particle Pal Plus utilises breakthrough digital imaging technology which provides a greater insight into the size and type of particulate in any fuel system. Air bubble elimination and shape recognition gives root cause particle analysis. A PPM Water sensor completes the package.

FS9V4-PPM
Ideal for on-site Diesel Fuel testing

  • Close up image of particulate

Harnessing the power of proven digital imaging technology plus water sensing technology.

We've embedded the latest in particle counting technology into our new Particle Pal Plus series. Giving ISO 11171 counts as well as 4, 6, 14, 21, 38 & 70 micron sizing and bubble elimination. Digital imaging, combined with advanced algorithms, sorts particles into fatigue wear, cutting wear and sliding wear categories to give root cause analysis. This powerful technology, when coupled with a Water PPM sensor for measuring water as Parts per Million, gives immediate on-the-spot insight into the condition of your fuel.

The image to the right is 4mm x 3mm and shows representative particulate that the human eye can't see, this is taken from the S120 particle counter embedded in the Particle Pal Plus range. (Images of fuel are not displayed on the screen).

Built-in Display

  • FS9V4 Screenshot
    FS9V4 Screenshot
  1. Clear and easy to read ISO code which changes between green, white and red to indicate the fuel cleanliness.

  2. Fuel cleanliness for each size category details the ISO code, the number of particles per millilitre and the bubbles detected.

  3. A Water PPM Sensor gives the water parts per Million count.

  4. Additional settings allow control of the pump speed for priming and flushing, data logging, ISO cleanliness alarm limits and changing the time zone.

  5. Fluid cleanliness is trended over time to show how its condition changes.

  6. Particles are analysed and sorted into fatigue wear, cutting wear, sliding wear and fibre identification to give root cause analysis.

  7. Open a full-size QR code which can be scanned from your mobile device to open the last 5 tests as a fully tabular and graphical report on particlepal.com.

 


 

  • particlepal.com on mobile

Watch the demo video

Online reporting tool

Particle Pal Plus has the ability to generate a QR code, representing the 5 most recent tests. When scanned on a mobile device this will open a fully tabulated and graphical report based on those readings hosted on particlepal.com. After viewing the report you can choose to create or log into your user account, then save your reports.

Additional test information can be added to saved reports for future retrieval, as well as optionally displaying your own company name and logo before being shared with third parties such as your own customers.

 


 

Digital Imaging Particulate Counter

Capable of broad size determination from 4, 6, 14, 21, 38 & 70 micron counts. Air bubble and water droplet elimination. Shape determination to identify fatigue, sliding or cutting wear as well as fibre identification.

Battery Life

Internal rechargeable lithium batteries provide up to ten hours of use.

Water Sensor

Water in fuel is a contaminant that can contribute to microbial growth and encourage further contamination, from solids to rust. The inbuilt water sensor shows the water content of fuel in PPM.

Water content

Displayed as parts per million (PPM). Helps inform whether water removal is actually required.

Particulate analysis.

The Atten2 digital imaging particle counter gives advanced size and shape recognition for any sample.    Counting particulate in fuel and virtually any oil up to 320cSt, the Atten2 device also eliminates air bubbles, making it ideal for heavy lube and gear oil applications in cold temperatures. Reporting 4, 6, 14, 21, 38 & 70 micron counts as well as categorising any particle greater than 20 microns into Fatigue Wear, Sliding Wear, Cutting Wear and Fibres.

Particle Pal Plus - Advanced Fuel Analysis - Technical Information

Fluid Compatibility Synthetic Oils, Organic Oils, Mineral Oils & Diesel Fuel (320 cSt viscosity limit)
Display Information Particulate: ISO 11171, SAE AS4059 & NAS 1638, bubble elimination and particulate wear analysis.
Water sensing: Water is displayed in parts per million (PPM).
Modes of Operation High pressure live system sampling (up to 350 bar) - via a high pressure adaptor.
Bottle sampling and tank sampling.
Data All data stored locally with an option to export to CSV or PDF.